Report for Greenbury Point (Maryland) - 1867
| General |
| District: | 5th |
| Inspector: | J. M. Berrien, Inspector, 5th District. |
| Location: | Near Annapolis, MD |
| Date of Report: | 09/14/1867 |
| Latitude: | |
| Longitude: |
| Premises |
| Site: | |
| Date of Reservation: | |
| Date of Deed: | |
| Date of Permission: | |
| Date of Lease: | |
| Area of the Entire Site: | |
| Area Inclosed: | |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | |
| Inclosures to Premises / Type of Fence: | House only is enclosed by a board fence. |
| Wharf or Landing on Premises: | |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | |
| Distance to Nearest Road: | |
| Distance to Post Office: | |
| Distance to Village: | |
| Facilities for Public Conveyance: | |
| Facilities for Private Conveyance: | |
| Means Used for Support of Lantern: | Keeper's dwelling |
| Number of Separate Lights: | 1 |
| First Built or Established: | |
| Last Rebuilt, Repaired, or Renovated: | |
| Condition at This Date: | |
| Shape of Tower in Plan: | |
| Form of Tower: | |
| Height from Base to Ventilator Ball: | |
| Height of Focal Plane Above Mean High Water: | |
| Background of Lighthouse as Seen from Sea: | |
| Color of Tower: | |
| Color of Tower/ How Produced: | |
| Tower Connection: | |
| Object of Navigation: | |
| Building Materials: | |
| General Description: | |
| Wall Thickness at Base: | |
| Wall Thickness at Parapet: | |
| Diameter at Base: | |
| Diameter at Parapet: | |
| Kind of Stairway and Steps: | |
| Number of Landings: | |
| Size of Glass: | |
| Number of Windows and Size of Sash: | |
| Number of Doors: | |
| Kind of Foundation and Depth Below Surface: | |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: |
| Ventilators |
| Location / Number: | |
| Ladders / Cleaning Arrangement: | There was one ladder for outside use. |
| Curtain Hooks / Hanger: | No |
| Watchroom |
| How is Watchroom Fitted: | |
| How is Relief Called: | No bell for calling relief. |
| Where is Call System Led: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | |
| Name of Maker: | |
| Year Made: | |
| Marks and Number: | |
| Order of Apparatus: | 6th |
| Inside Diameter: | |
| Light Characteristic: | Fixed white |
| Time of Revolution: | |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | |
| Number of Panels: | |
| Number of Flash Panels: | |
| Arc of Each: | |
| Number of Elements in Central Drum: | |
| Number of Prisms Above Center Drum: | |
| Number of Prisms Below Center Drum: | |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | |
| Service Table: | |
| Draft Tube Description: | |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | Lens of 6th order. Fountain or constant level lamp. |
| Type of Illuminant: | |
| Number of Spare Lamps: | 1, in good condition |
| Number of Spare Burners: | 1, in good condition |
| Candle Power: |
| Closets and Store Rooms |
| Tower Closet Use: | |
| Oil House Description: | |
| Oil House Inside Dimension: | |
| Oil House Construction Material: | |
| Oil House Capacity: | |
| Other (Describe): | There is a closet provided for the preservation of utensils, wicks, chimneys and cleaning materials. Paints, oils, spirits of turpentine, paint-brushes, etc. are kept in a corner of the oil cellar. |
| Suitability: |
| Dwelling |
| Location: | |
| Coloring: | |
| Construction Materials: | |
| Number of Rooms: | |
| Number of Dwellings: | |
| Heating Plant: | |
| Number of Keepers: | |
| Furnished Quarters: | |
| NOT Furnished Quarters: | |
| Outhouses: | |
| Outhouse Coloring: | |
| Paths and Walks: | |
| Area Inclosed: | |
| Area of Garden: | |
| Area Timber or Shrubbery: | |
| Cultivation Area Available: | |
| Area Cultivated: | Keeper cultivates a small patch. |
| Character of Surroundings: | |
| Stove, Maker: | |
| Stove, Size: | |
| Sink, Maker: | |
| Sink, Size: | |
| Pump, Maker: | |
| Pump, Size: | |
| Lamps: | There is a Regulation time piece in good condition kept in the sitting room of the dwelling. |
| Boats |
| Boat Number: | 0 |
| Type: | |
| Length: | 6' |
| Width: | 19' |
| When Built: | |
| Date Harbored at Station: | |
| Sails: | False |
| Suited to Work: | Requires a new bottom |
| Miscellaneous |
| General Information: | Appendages in pretty good condition. |
| Boats on Station: |
| Condition |
| Lantern: | In good condition. |
| Illuminating Apparatus: | The lens was perfectly clean in all its parts. |
| Service Lamp: | In good condition in all respects. |
| Oil: | Specimen examined; it was found to be clear & free from all objectionable matter. |
| Service Lamp Burner: | Free from gummy or burnt oil, clean & the wicks well trimmed. |
| Service Lamp Burner Level: | Burner was found to be slightly out of level. |
| Plate Glass: | Clean & free from scratches & stains. |
| Lens Cover: | It was on; was clean; made of linen sheeting & kept in the lantern room when not in use. |
| Lantern Curtains: | None |
| Carillon or Alarm Bell: | No alarm bell |
| Rod Lamp: | None |
| Dwelling: | Dwelling seems to want a general repair. |
| Stairway and Landing: | Clean |
| Inside of Tower: | |
| Glazing of Dwelling: | In bad condition. |
| Improvements Needed: | A general repair is needed. The dome leaks, & the roof also leaks. Ceiling plaster in some of the rooms is falling down. |
| Outhouses: | Clean, but requires some repairs. |
| Boathouse: | None |
| Grounds: | Very good. They are very clean & wear a neat appearance. |
| Equipment Care |
| Does Keeper Understand the Use and Care of | |
| Lens: | It is not allowed to touch the lens improperly. |
| Lantern and Trap Doors: | They fit tightly |
| Watch or Trimming Room: | None to be seen at time of making the inspection. |
| Lucernes or Matches: | None of the above named articles were to be seen at the Inspection. |
| Heater: | Keeper understands the use of the heater. |
| Ventilation: | Keeper understands use of the ventilators & how to air the bldg. |
| Dome: | Painted according to instructions. Lightning rod conductor was in good order & was led into the ground. |
| Oil Room |
| Oil Room Condition: | In good condition; & no appearance of waste of oil |
| Oil Carriers: | In good condition & arranged in order for use. |
| Number of 100 Gallon Oil Butts: | |
| Number of 50 Gallon Oil Butts: | 2 |
| Number of Small Butts for Waste Oil: | |
| Number of Dripping Buckets: | 2 |
| Number of Oil Tanks: | 2, holding 100 gallons |
| Oil Butts Made According to Regulation: | They are so made |
| Oil Butt Covers: | Gutters were filled. Keeper understands use of covers & cocks. |
| Drip Bucket Placement: | A dripping bucket was so hung. |
| Oil Butt Platform: | There is a plank placed btwn the bottom of the butts & the floor. |
| Empty Oil Butts: | There was no empty oil butt. |
| Tool Chests and Presses |
| Cleaning Materials Put Away: | They are so put up & packed. |
| Paints Separate: | They are kept separate |
| Tool Chest: | None |
| Tool Condition: | |
| Tools Free from Rust: | |
| Closets Clean: | Kept properly aired |
| Service Box In Good Order: | Yes |
| Trimming Scissors Clean: | Yes |
| Brushes and Floor Clothes: | Yes |
| Lantern Condition: | In good order |
| Keeper and Assistants |
| Keeper Appearance: | He was very well dressed. |
| Keeper Interested in Duties: | He manifested much interest. |
| Keeper Capacity for Duties: | Shows capacity & seems to wish to gain information. |
| Keeper Understanding of Regulations: | Seems to understand & to wish to conform to them. |
| Keeper Complaints: | |
| Keeper Family: | Keeper's family occupy dwelling with him. |
| Keeper Name: | James B. Taylor |
| Keeper Age: | Young |
| Keeper Present or Absent: | Present |
| Number of Assistants: | No assistant allowed. |
| Assistants Attend to Duty: | |
| Assistants Capability: | |
| Assistants Complaints: | |
| Assistants Family: | |
| Assistant Keeper Names: | |
| Did Principal and Assistant Keepers Accompany the Inspector?: | Keeper accompanied me through the bldg & over the grounds while making the inspection. |
| Account and Regulations Books |
| Account Books | |
| Daily Expenditures Posted: | Yes |
| Quarterly Returns on Hand: | Yes |
| Receipt and Expenditure Accounts Kept: | Yes |
| Shipwreck and Vessels Passed Book: | None are kept |
| Regulations, Instructions, and Directions | |
| Rules and Regulations Copies: | 1 |
| Instructions and Directions Copies: | 1 |
| Placard Directions Copies: | 1 |
| Notice to Visitors Copies: | 1 |
| Summary of Duties: | 1 |
| Index of Instructions: | 1 |
| Guide for Mixed Paints: | 1 |
| Directions for Purifying Water: | 1 |
| Placards Easily Visible: | Yes |
| Books Easily Accessible: | Yes |
| Blank Books and Forms: | |