Report for North Point Western Tower (Maryland) - 1867
| General |
| District: | 5th |
| Inspector: | J. M. Berrien, Inspector, 5th District. |
| Location: | Patapsco River. |
| Date of Report: | 09/14/1867 |
| Latitude: | |
| Longitude: |
| Premises |
| Site: | |
| Date of Reservation: | |
| Date of Deed: | |
| Date of Permission: | |
| Date of Lease: | |
| Area of the Entire Site: | |
| Area Inclosed: | |
| Character of Soil: | |
| Distance of tower from Nearest High-Water Mark: | |
| Inclosures to Premises / Type of Fence: | Enclosed with board & rail fence. |
| Wharf or Landing on Premises: | |
| Road to Land or Wharf Chararacter of and Distance: | |
| Means to Reach Light Station: | |
| Distance to Nearest Road: | |
| Distance to Post Office: | |
| Distance to Village: | |
| Facilities for Public Conveyance: | |
| Facilities for Private Conveyance: | |
| Means Used for Support of Lantern: | Detached tower |
| Number of Separate Lights: | 1 |
| First Built or Established: | |
| Last Rebuilt, Repaired, or Renovated: | |
| Condition at This Date: | |
| Shape of Tower in Plan: | |
| Form of Tower: | |
| Height from Base to Ventilator Ball: | |
| Height of Focal Plane Above Mean High Water: | |
| Background of Lighthouse as Seen from Sea: | |
| Color of Tower: | |
| Color of Tower/ How Produced: | |
| Tower Connection: | |
| Object of Navigation: | |
| Building Materials: | |
| General Description: | Built of stone "random" laid as nearly as I could tell. It leaks. |
| Wall Thickness at Base: | |
| Wall Thickness at Parapet: | |
| Diameter at Base: | |
| Diameter at Parapet: | |
| Kind of Stairway and Steps: | Of stone & whitewashed. |
| Number of Landings: | |
| Size of Glass: | In pretty good condition. There is 1 pane out. |
| Number of Windows and Size of Sash: | Wood - in good condition. |
| Number of Doors: | |
| Kind of Foundation and Depth Below Surface: | |
| Character of Soil Surrounding the Lighthouse: | |
| Soil Susceptibility: | |
| Miscellaneous Remarks: |
| Ventilators |
| Location / Number: | |
| Ladders / Cleaning Arrangement: | 1 ladder - no hooks at end of ladder. |
| Curtain Hooks / Hanger: | No |
| Watchroom |
| How is Watchroom Fitted: | |
| How is Relief Called: | No bell for calling the relief. |
| Where is Call System Led: |
| Illuminating Apparatus |
| Kind of Apparatus: | |
| Intensity in Candles: | |
| Name of Maker: | |
| Year Made: | |
| Marks and Number: | |
| Order of Apparatus: | 6th |
| Inside Diameter: | |
| Light Characteristic: | Fixed white |
| Time of Revolution: | |
| Flash Interval: | |
| Duration of Flash: | |
| Arc of Each Fixed Part: | |
| Number of Panels: | |
| Number of Flash Panels: | |
| Arc of Each: | |
| Number of Elements in Central Drum: | |
| Number of Prisms Above Center Drum: | |
| Number of Prisms Below Center Drum: | |
| Does Apparatus Revolve?: | False |
| Is There a Revolving Belt?: | False |
| Revolving Panels: | |
| How Flash is Produced: | |
| Number of Vertical Elements Panel: | |
| Fixed Lens Covered: | |
| Pedestal: | |
| Service Table: | |
| Draft Tube Description: | |
| Revolving Machinery: | |
| Standby and Description: | |
| Chariot Float or Balls: | |
| Chariot Description: | |
| Length of Drop Tube: | |
| Clock Weight: | |
| Length of Winding Time: | |
| Drive During Rewind: | |
| Machinery Protection: | |
| Regulated: | |
| Lens Protection: | |
| How Color is Produced: | |
| Red Sectors Description: | |
| Where Color Attached: | |
| Form of Colored Glass: | |
| Lamp Description: | Lens of the 6th order - Franklin lamp |
| Type of Illuminant: | |
| Number of Spare Lamps: | 2, in good condition |
| Number of Spare Burners: | 2, in good condition. |
| Candle Power: |
| Closets and Store Rooms |
| Tower Closet Use: | |
| Oil House Description: | |
| Oil House Inside Dimension: | |
| Oil House Construction Material: | |
| Oil House Capacity: | |
| Other (Describe): | There is a closet provided for the preservation of utensils, wicks, chimneys and cleaning materials. Paints, oils, spirits of turpentine, paint-brushes, etc. are kept in the oil room by themselves. |
| Suitability: |
| Dwelling |
| Location: | |
| Coloring: | |
| Construction Materials: | |
| Number of Rooms: | |
| Number of Dwellings: | |
| Heating Plant: | |
| Number of Keepers: | |
| Furnished Quarters: | |
| NOT Furnished Quarters: | |
| Outhouses: | |
| Outhouse Coloring: | |
| Paths and Walks: | |
| Area Inclosed: | |
| Area of Garden: | |
| Area Timber or Shrubbery: | |
| Cultivation Area Available: | |
| Area Cultivated: | Keeper cultivates all of it. |
| Character of Surroundings: | |
| Stove, Maker: | |
| Stove, Size: | |
| Sink, Maker: | |
| Sink, Size: | |
| Pump, Maker: | |
| Pump, Size: | |
| Lamps: | There is a regulation clock in good condition - kept in the sitting room of the dwelling. |
| Miscellaneous |
| Access to Lighthouse: | |
| Distance and Direction: | |
| Miscellaneous Remarks: | A boat seems to be needed at this station. There are times when a boat is necessary to enable the Keeper to get from one tower to the other. |
| Condition |
| Lantern: | In good condition. |
| Illuminating Apparatus: | Lens was not clean, owing to sickness of Keeper who was confined to his bed. |
| Service Lamp: | Tolerably good condition. |
| Oil: | Specimen examined. It was clear & clean, it had been filtered. |
| Service Lamp Burner: | Good condition |
| Service Lamp Burner Level: | The burner was found to be somewhat out of level. |
| Plate Glass: | Not clean; Keeper sick as before stated. |
| Lens Cover: | It was on; made of cotton ticking. Hung up in the lantern room when not in use. It was clean. |
| Lantern Curtains: | No curtains here. |
| Carillon or Alarm Bell: | No alarm bell. |
| Rod Lamp: | No rod lamp. |
| Dwelling: | The roof of the dwelling is reported to leak badly in storms. |
| Stairway and Landing: | Tolerably clean |
| Inside of Tower: | Inside of tower was whitewashed. |
| Glazing of Dwelling: | Some panes of glass are wanted. |
| Improvements Needed: | Repairs to roof are needed. It leaks badly as the Keeper states. |
| Outhouses: | In pretty good condition. |
| Boathouse: | None |
| Grounds: | Very good. They appear to be well taken care of. |
| Equipment Care |
| Does Keeper Understand the Use and Care of | |
| Lens: | It is not allowed to touch the lens improperly. |
| Lantern and Trap Doors: | These doors fit tightly. |
| Watch or Trimming Room: | None of these articles were to be seen at the time of inspection. |
| Lucernes or Matches: | Matches were seen, & the attention of the Keeper called to the impropriety of this being allowed to be about. |
| Heater: | |
| Ventilation: | Keeper understands the use of the ventilators & how to air the bldg. |
| Dome: | Painted according to instructions. Lightning conductor in good condition & led into the ground. |
| Oil Room |
| Oil Room Condition: | In good condition, well ventilated & no waste of oil |
| Oil Carriers: | In good condition. |
| Number of 100 Gallon Oil Butts: | 1 |
| Number of 50 Gallon Oil Butts: | 1 |
| Number of Small Butts for Waste Oil: | |
| Number of Dripping Buckets: | 3 |
| Number of Oil Tanks: | 2, holding 50 gallons |
| Oil Butts Made According to Regulation: | They are so made. |
| Oil Butt Covers: | Gutters were not filled. Instructed the Keeper on the subject of filling them. |
| Drip Bucket Placement: | There was a dripping bucket to one butt only. |
| Oil Butt Platform: | They were clear of the masonry, on a raised platform. |
| Empty Oil Butts: | There was no empty oil butt. |
| Tool Chests and Presses |
| Cleaning Materials Put Away: | Yes |
| Paints Separate: | Kept separate |
| Tool Chest: | No |
| Tool Condition: | |
| Tools Free from Rust: | |
| Closets Clean: | They are properly aired. |
| Service Box In Good Order: | Tolerably good order |
| Trimming Scissors Clean: | Tolerably clean, will look better no doubt, when Keeper can attend. |
| Brushes and Floor Clothes: | Tolerably good order; in their proper places. |
| Lantern Condition: | Tolerably good. |
| Keeper and Assistants |
| Keeper Appearance: | Could not ascertain as he was sick in bed. |
| Keeper Interested in Duties: | He does |
| Keeper Capacity for Duties: | He does as far as I could see in the interview I had with him. |
| Keeper Understanding of Regulations: | I think he understands & wishes to conform to them. |
| Keeper Complaints: | |
| Keeper Family: | Keeper's family resides with him. |
| Keeper Name: | Thomas Hamlin |
| Keeper Age: | Middle aged |
| Keeper Present or Absent: | Keeper was sick in bed with "chills & fever". |
| Number of Assistants: | No assistant allowed. |
| Assistants Attend to Duty: | |
| Assistants Capability: | |
| Assistants Complaints: | |
| Assistants Family: | |
| Assistant Keeper Names: | |
| Did Principal and Assistant Keepers Accompany the Inspector?: | He was sick in bed. I had an interview with him in his room. |
| Account and Regulations Books |
| Account Books | |
| Daily Expenditures Posted: | Yes |
| Quarterly Returns on Hand: | Yes |
| Receipt and Expenditure Accounts Kept: | Yes |
| Shipwreck and Vessels Passed Book: | Not kept by the Keeper |
| Regulations, Instructions, and Directions | |
| Rules and Regulations Copies: | 1 |
| Instructions and Directions Copies: | 1 |
| Placard Directions Copies: | 1 |
| Notice to Visitors Copies: | 1 |
| Summary of Duties: | 1 |
| Index of Instructions: | 1 |
| Guide for Mixed Paints: | 1 |
| Directions for Purifying Water: | 1 |
| Placards Easily Visible: | Yes |
| Books Easily Accessible: | Yes |
| Blank Books and Forms: | |